The short answer: yes, solar can run an RV air conditioner, for a few hours a day, if you build the whole electrical system around it. Running one all afternoon or all night from solar alone takes more roof than almost any RV has. Most people who do it treat the battery as the power source and solar as one of several ways to refill it.
Power required
A typical 13,500 BTU rooftop air conditioner draws about 1,500 W while the compressor runs. Makers and installers quote a range of roughly 1,300 to 1,800 W depending on the model and the heat. A 15,000 BTU unit draws about 1,800 W.
Starting the compressor takes more: commonly 2,800 to 3,500 W for a moment. That start-up surge decides whether your inverter can run the unit at all.
For comparison, a simple van with lights, a fan and a 12 V fridge uses about 800 Wh in a whole day. An air conditioner uses that in about half an hour.
Battery drain
The air conditioner runs through an inverter, which adds about 10% in losses. So each hour of compressor time takes about 1,667 Wh out of the battery. The table shows what that means, using lithium batteries at 80% depth of discharge and a summer day with 6 peak sun hours.
| Compressor run time | Energy from battery | Lithium battery | Solar to replace it | Roof space |
|---|---|---|---|---|
| 1 hour | 1,667 Wh | 163 Ah at 12 V 2 × 100 Ah | 425 W 3 × 200 W | 37 sq ft 3.4 m² |
| 2 hours | 3,333 Wh | 326 Ah at 12 V 4 × 100 Ah | 851 W 5 × 200 W | 62 sq ft 5.7 m² |
| 4 hours | 6,667 Wh | 651 Ah at 12 V 7 × 100 Ah | 1,701 W 9 × 200 W | 111 sq ft 10.3 m² |
| 8 hours | 13,333 Wh | 1,302 Ah at 12 V 14 × 100 Ah | 3,402 W 18 × 200 W | 221 sq ft 20.6 m² |
“Run time” is the time the compressor is actually working. In mild weather it cycles on and off, so eight hours of comfortable cooling overnight might be four or five hours of run time. In real heat it barely stops. Micro-Air, which makes soft starters, estimates 400 to 800 Ah of lithium for an eight-hour night in light to moderate conditions, which is consistent with the table once cycling is allowed for.
Inverter size
Using our inverter sizing rule (20% headroom, and a surge capacity of twice the rating):
- A 13,500 BTU unit needs a 2,000 W pure sine inverter.
- A 15,000 BTU unit needs a 3,000 W inverter.
Two cautions. First, cheaper inverters cannot deliver twice their rating at start-up, so check the surge figure. A soft-start device on the air conditioner cuts the start-up surge by as much as 70% and makes this much less of a gamble. Second, a 2,000 W inverter draws about 185 A from a 12 V battery at full power. That needs very heavy cable and at least two 100 Ah lithium batteries in parallel just to supply the current. Systems built for air conditioning are usually easier at 24 V or 48 V.
Practical setups
Take the edge off: 1 to 2 hours a day
Cool the rig down before bed, or keep a pet safe during a short stop.
- 4 × 100 Ah of lithium (or the same capacity in larger batteries)
- 2,000 W inverter, with a soft start on the air conditioner
- 1,000 W of solar replaces two hours of run time on a sunny summer day, and driving with a DC-DC charger fills the gaps
This is within reach of a large van or a mid-size trailer, and it is what most “solar air conditioning” builds really are.
An afternoon of cooling: about 4 hours
- 651 Ah of lithium at 12 V, better built as a 24 V or 48 V bank
- 1,800 W of solar, around 111 square feet of panels
Only the largest motorhomes and fifth wheels have that much clear roof. Everyone else recharges from the alternator, a generator or a campsite hook-up for part of it.
All day or all night: 8 hours and more
At this point the battery bank costs more than many trailers, and no vehicle roof holds the solar to refill it daily. Use shore power or a generator, and let solar handle everything else.
Ways to need less
- Start with shade and insulation. Parking in shade, reflective window covers and a roof vent fan pulling air through cost a fraction of the battery they save.
- Cool a smaller space. Closing off the bed area with a curtain cuts the work the unit has to do.
- Look at the unit itself. Newer inverter-compressor and DC-powered air conditioners use less than a conventional rooftop unit and have little or no start-up surge. Compare running watts on the spec sheets.
- Move with the weather. Altitude and coastlines are the cheapest air conditioning there is.
Try it with your own numbers
Add an air conditioner to your appliance list in the system planner and set the hours you want. It shows the battery, solar, inverter and cables for the whole rig, and warns you when the roof or the battery current becomes the limit.
Common questions
How many solar panels does it take to run an RV air conditioner?
To replace the energy from four hours of a 13,500 BTU unit on a sunny summer day you need about 1,700 W of panels: nine 200 W panels and roughly 110 square feet of roof. Panels cannot run the air conditioner directly. They recharge the battery that does.
How many lithium batteries do I need to run an RV air conditioner?
Each hour of compressor run time takes about 1,670 Wh from the battery, close to two 100 Ah lithium batteries at 80% depth of discharge. Two hours needs four batteries and four hours needs seven. You also need at least two in parallel just to supply the current a 2,000 W inverter draws.
Will a soft start let me run the air conditioner on a smaller system?
It reduces the start-up surge, which can let a smaller inverter or generator start the compressor. It does not reduce the power used while running, so the battery and solar needed stay the same.
Can I run the air conditioner while driving?
Sometimes. A DC-DC charger or a second alternator can supply part of the load while the engine runs, and the battery covers the rest. The limit is the alternator's spare output, which varies widely between vehicles, so check its rating before you plan around it.