The short answer: add up the watts of everything that will run through the inverter at the same moment and add 20%. Then check the result against the start-up surge of your biggest motor and against what your battery can deliver. For most RVs the answer is 2,000 W.
Step 1: make the load list
Only AC appliances count: the ones with a mains plug. Lights, fans, the water pump and a 12 V fridge run straight from the battery and never touch the inverter.
Write down the running watts of each AC appliance, then decide which ones you will really use together. This is the step that saves money. If you are happy to wait for the kettle to finish before starting the microwave, you need an inverter for one of them, not both.
Use the input power from the rating plate, not the number on the box. A microwave sold as “1,000 W” delivers 1,000 W of cooking power and draws about 1,500 W to do it.
Step 2: allow for surge power
Anything with a motor or compressor takes a brief kick of extra power to start. Typical multiples of running power are:
- Resistive loads (kettle, toaster, heater, hair dryer): no surge.
- Electronics (laptop, TV, chargers): negligible.
- Fridges and freezers: several times running power, for a fraction of a second.
- Air conditioners: a 13,500 BTU rooftop unit runs at about 1,500 W and can ask for 2,800–3,500 W at start-up.
Most inverters can deliver about twice their rated power for a few seconds. So a 2,000 W inverter can usually start a load that surges to 4,000 W, provided nothing else is drawing much at that moment. Check the surge figure for the model you buy, because cheaper inverters manage less.
A soft-start device fitted to an air conditioner can reduce its start-up surge by as much as 70%. It is often the cheapest way to run air conditioning from a smaller inverter.
Worked examples
The inverter column is the result of the sum above: total running watts plus 20%, or half the surge, whichever is larger, rounded up to a common size. The last three columns are what the inverter then asks of a 12 V system at full power, with a 5 ft (1.5 m) battery cable.
| What runs together | Running | Start-up | Inverter | Battery current | Cable and fuse | 100 Ah lithium batteries needed |
|---|---|---|---|---|---|---|
| Laptop, TV and phone chargers | 180 W | 180 W | 300 W | 28 A | 10 AWG (6 mm²), 35 A fuse | 1 |
| Drip coffee maker | 1,000 W | 1,000 W | 1,500 W | 139 A | 2 AWG (35 mm²), 175 A fuse | 2 |
| Microwave (1,000 W cooking power) | 1,500 W | 1,500 W | 2,000 W | 185 A | 1/0 AWG (70 mm²), 250 A fuse | 2 |
| Microwave with TV and laptop on | 1,600 W | 1,600 W | 2,000 W | 185 A | 1/0 AWG (70 mm²), 250 A fuse | 2 |
| Induction cooktop, one burner on high | 1,800 W | 1,800 W | 3,000 W | 278 A | 3/0 AWG (95 mm²), 350 A fuse | 3 |
| 13,500 BTU air conditioner | 1,500 W | 3,000 W | 2,000 W | 185 A | 1/0 AWG (70 mm²), 250 A fuse | 2 |
| Air conditioner and microwave together | 3,000 W | 4,500 W | 4,000 W | 370 A | Too large for one cable at 12 V | 4 |
The last row shows why big loads push people to 24 V or 48 V. At 12 V the current is so high that the cable, fuse and battery bank all become awkward. At 24 V the same inverter draws half the current.
Step 3: check the battery limits
An inverter cannot make power. It can only convert what the battery supplies, and batteries have limits.
Lithium batteries have a battery management system (BMS) that disconnects above a set current. For most 12 V 100 Ah batteries that limit is 100 A continuous, which is about 1,100 W through an inverter. Batteries in parallel add their limits, so the final column of the table is the smallest bank that can feed each inverter at full power.
Lead-acid batteries have no hard cut-off, but their voltage sags under heavy load and the inverter shuts down on low voltage. They also deliver less capacity when drained quickly. As a rule of thumb, keep the inverter’s draw below a quarter of the bank’s amp-hour rating.
Energy matters as well as current. At full power, a 2,000 W inverter uses as much energy in half an hour as a 100 Ah lithium battery holds. The runtime calculator shows how long your bank lasts with any load.
Step 4: wiring
The cable between battery and inverter carries more current than anything else in the vehicle. Three rules keep it safe:
- Keep it short. Mount the inverter as close to the battery as ventilation allows. Every extra foot costs voltage and money.
- Size the cable for the inverter’s full rating, not for what you plan to run. Someone will plug in something bigger one day.
- Fuse it at the battery. The fuse protects the cable from a short circuit, so it belongs at the battery end of the positive cable. On a lithium bank, use a fuse with a high interrupt rating, such as a Class T.
The inverter’s manual will state a minimum cable size and a fuse rating. If it asks for more than the table above, follow the manual. The wire gauge calculator handles other lengths, voltages and cable types.
The output side is mains voltage. The sockets fed by an inverter can injure or kill exactly like a household socket. Wiring beyond plugging an appliance into the inverter’s own outlets should be done or checked by a qualified electrician.
Size yours
Put your own appliances into the inverter size calculator. It runs the surge check, shows the battery current at 12, 24 or 48 V, and sizes the cable and fuse for your cable length.
Common questions
Is a 2,000 W inverter enough for an RV?
For most RVs, yes. It runs a microwave, a coffee maker, a hair dryer or an induction burner on low, one at a time, plus small electronics. It will also start many 13,500 BTU air conditioners, especially with a soft-start device fitted. It will not run two large appliances together.
Can I run a microwave on a 1,000 W inverter?
Not a full-size one. A microwave sold as 1,000 W draws about 1,500 W from the socket. A small 700 W microwave draws about 1,050 W, which is still over the limit. You need a 2,000 W inverter for a normal microwave.
How much power does an inverter use when nothing is running?
It depends on the model: usually somewhere between 10 and 50 W just for being switched on. Over 24 hours that can add up to more than a 12 V fridge uses, so turn the inverter off when you are not using it.
Should I buy an inverter or an inverter-charger?
An inverter-charger also charges the battery from shore power and switches over automatically when you plug in. It costs more but replaces a separate charger and transfer switch. If you rarely use campsites with hook-ups, a plain inverter is enough.